Summary Before operating the Chemical Oxygen Self Rescuer, the staff must receive professional training and detailed instructions to understand the correct use and procedures of ...
Before operating the Chemical Oxygen Self Rescuer, the staff must receive professional training and detailed instructions to understand the correct use and procedures of the Chemical Oxygen Self Rescuer. When you start with Chemical Oxygen Self Rescuer, it should be at least two people. When carbon dioxide is absorbed, it will generate heat, especially when working in a harsh environment. This is completely normal and fully demonstrates Chemical Oxygen Self Rescuer. In good working condition.
In case of emergency, if the gas is excessively consumed, the breathing is difficult or the oxygen supply function is invalid, according to the manual air supply valve, the respiratory system can be supplemented with a certain amount of oxygen, and immediately after the oxygen supply function fails, the dangerous area is immediately evacuated. The pre-pressure gauge was observed every 15 minutes to check the oxygen content of Chemical Oxygen Self Rescuer.
When the pressure in the Chemical Oxygen Self Rescuer cylinder is 4-6MPA, the alarm starts to have a low-pressure alarm. The alarm sound does not have to be evacuated, but about 75% of the oxygen has been used up. If it is not evacuated now, it must be Always observe the front pressure gauge. When the pressure is 1MPA, about 95% of the oxygen has been used up. At this time, it must be evacuated, otherwise it will threaten the user's life safety.