How Do Mine Workers Use
Rescue Equipment Chemical Oxygen Self Rescuer?
Mine workers use
Chemical Oxygen Self Rescuers for the following steps:
1. The Chemical Oxygen Self Rescuer should be carried on the belt;
2. Remove the protective cover when using the
Self Rescuer;
3. Use the thumb to pull up the red wrench, pull off the sealing strip, and open the sealing strip of the self rescuer;
4. Open the upper shell of the
Chemical Oxygen Self Rescuer and throw it away;
5. Take out the Rescue Equipment self-rescuer and throw away the lower shell;
6. Use your thumb to open the starter wrench of the initial oxygen generator and turn it clockwise about 150°;
7. Unplug the mouthpiece;
8. Bite the mouth with the breathing mouthpiece. At this time, if the airbag bag has been inflated, you can clip the nose clip and breathe through your mouth; if the airbag bag is not inflated, you should exhale to the self-rescuer to inflate the airbag, and then clip the nose. mouth breathing;
9. Wear a headband;
10. After wearing, wear the
Rescue Equipment Chemical Oxygen Self Rescuer and evacuate the disaster area at a constant speed.